S-800W ACDC switching power supply 33.3A-66.6A

Features:

· Universal voltage input range: 90-132VAC/180-264VAC

· Protection type: short circuit/overcurrent

· Natural air cooling

· Work efficiency up to 86%

· 100% full-load burn-in test

· 2-year warranty

S-800 800W Switching Power Supply
Project Technical index
Output DC voltage 12V 24V 36V 48V
Rated current 66.5A 33.3A 22.2A 16.6A
Rated power 798W 799.2W 799.2W 796.8
Ripple and noise ① <150mV <150mV <240mV <240mV
Voltage accuracy ±1%
Output voltage regulation range ±10%
Load adjustment rate <±1.2% <±1% <±0.5% <±0.5%
Linear adjustment rate <±1%
Input Voltage range 90-132/180-264VAC 47Hz~63Hz;254VDC~370VDC
Efficiency (typical) ② >82% >84% >86% >86%
Working current <12A 115VAC    <7.8A 230VAC
Impulse current  110VAC: 25A    220VAC: 50A
Start, rise, hold time 200ms、50ms、20ms :230VAC
Protect overload protection 105% – 135% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again
Overvoltage protection Close output when ≥ 115% – 145%
Short circuit protection Close output
Over temperature protection Rth3: ≥ 70 ℃ fast rotation of fan, ≥ 90 ℃ close output
Environmental Science Working temperature and humidity -10℃~+50℃;20%~90RH
Storage temperature and humidity -20℃~+85℃;10%~95RH
Safety regulations Withstand voltage Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute
Leakage current Input output < 6mA at 1.5kVac
Leakage current Input output at 220VAC < 1mA
Isolation resistance Input output, input shell, output shell: 500VDC / 100M Ω
Other size 241*125*65mm
Net weight / gross weight 1268/1358g
Remarks ① Ripple and noise measurement method: use a 12 “twisted pair, and connect 0.1uF and 47uF capacitors in parallel at the terminal, and measure at 20MHz bandwidth. ② The efficiency is tested at an input voltage of 230VAC, rated load, and an ambient temperature of 25 ℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear regulation test method: under rated load from low voltage to high voltage test load regulation test method: from 0% – 100% rated load. The start-up time is measured under the cold start state. The quick and frequent switch on and off may increase the start-up time. When the operating altitude is higher than 2000m, the operating environment temperature needs to be reduced by 5 ℃ / 1000m