S-600 600W Switching Power Supply | |||||
Project | Technical index | ||||
Output | DC voltage | 12V | 24V | 36V | 48V |
Rated current | 50A | 25A | 16.6A | 12.5A | |
Rated power | 600W | 600W | 600W | 600W | |
Ripple and noise ① | <150mV | <150mV | <240mV | <240mV | |
Voltage accuracy | ±1% | ||||
Output voltage regulation range | ±10% | ||||
Load adjustment rate | <±1.2% | <±1% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±1% | ||||
Input | Voltage range | 180-264VAC 47Hz~63Hz;254VDC~370VDC | |||
Efficiency (typical) ② | >82% | >84% | >86% | >86% | |
Working current | <5A 230VAC | ||||
Impulse current | 220VAC: 50A | ||||
Start, rise, hold time | 200ms、50ms、20ms :230VAC | ||||
Protect | overload protection | 105% – 135% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | |||
Overvoltage protection | Close output when ≥ 115% – 145% | ||||
Undervoltage protection | Close output | ||||
Over temperature protection | Rth3: ≥ 70 ℃ fast rotation of fan, ≥ 90 ℃ close output | ||||
Environmental Science | Working temperature and humidity | -10℃~+50℃;20%~90RH | |||
Storage temperature and humidity | -20℃~+85℃;10%~95RH | ||||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | |||
Leakage current | Input output < 6mA at 1.5kVac | ||||
Leakage current | Input output at 220VAC < 1mA | ||||
Isolation resistance | Input output, input shell, output shell: 500VDC / 100M Ω | ||||
Other | size | 241*125*65mm | |||
Net weight / gross weight | 1268/1358g | ||||
Remarks | ① Ripple and noise measurement method: use a 12 “twisted pair, and connect 0.1uF and 47uF capacitors in parallel at the terminal, and measure at 20MHz bandwidth. ② The efficiency is tested at an input voltage of 230VAC, rated load, and an ambient temperature of 25 ℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear regulation test method: under rated load from low voltage to high voltage test load regulation test method: from 0% – 100% rated load. The start-up time is measured under the cold start state. The quick and frequent switch on and off may increase the start-up time. When the operating altitude is higher than 2000m, the operating environment temperature needs to be reduced by 5 ℃ / 1000m |
All Products, Enclosed Type
S-600W ACDC switching power supply 25A-50A
Features:
· Universal voltage input range: 90-132VAC/180-264VAC
· Protection type: short circuit/overcurrent
· Natural air cooling
· Work efficiency up to 86%
· 100% full-load burn-in test
· 2-year warranty
Reviews