S-350W ACDC switching power supply 14.5A-29A

Features:

· Universal voltage input range: 90-132VAC/180-264VAC

· Protection type: short circuit/overcurrent

· Natural air cooling

· Work efficiency up to 84%

· 100% full-load burn-in test

· 2-year warranty

S-350 350W switching power supply
project Technical index
output DC voltage 5V 12V 18V 24V 36V 48V
Rated current 50A 29A 19.4A 14.5A 9.7A 7.3A
Rated power 250W 350W 350W 350W 350W 350.4W
Ripple and noise ① <150mV <150mV <150mV <150mV <240mV <240mV
Voltage accuracy ±2% ±1%
Output voltage regulation range ±10%
Load adjustment rate <±1.5% <±1.2% <±1.2% <±1% <±0.5% <±0.5%
Linear adjustment rate <±1%
input Voltage range 90-132VAC/180-264VAC 47Hz~63Hz;254VDC~370VDC
Efficiency (typical) ② >74% >82% >82% >84% >86% >86%
Working current <5.2 A 115VAC   <2.8A 230VAC
Impulse current 110VAC 25A, 220VAC: 50A
Start, rise, hold time 200ms、50ms、20ms :230VAC
protect overload protection 105% – 135% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again
Overvoltage protection Close output when ≥ 115% – 145%
Undervoltage protection Close output when ≤ 10% – 45%
Short circuit protection Close output
Over temperature protection Rth3: ≥ 65 ℃ fan start, ≥ 55 ℃ fan close, ≥ 80 ℃ close output (5v-15v) rth3: ≥ 70 ℃ fan start, ≥ 60 ℃ fan close, ≥ 85 ℃ close output (18v-48v)
Environmental Science Working temperature and humidity -10℃~+50℃;20%~90RH
Storage temperature and humidity -20℃~+85℃;10%~95RH
Safety regulations Withstand voltage Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute
Leakage current Input output < 6mA at 1.5kVac
Leakage current < 1.5mA at input-output 220VAC
Isolation resistance Input output, input shell, output shell: 500VDC / 100M Ω
Other size 215*114*50mm
Net weight / gross weight 874.1/936.3g
Remarks ① Ripple and noise measurement method: use a 12 “twisted pair, and connect 0.1uF and 47uF capacitors in parallel at the terminal, and measure at 20MHz bandwidth. ② The efficiency is tested at an input voltage of 230VAC, rated load, and an ambient temperature of 25 ℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear regulation test method: under rated load from low voltage to high voltage test load regulation test method: from 0% – 100% rated load. The start-up time is measured under the cold start state. The quick and frequent switch on and off may increase the start-up time. When the operating altitude is higher than 2000m, the operating environment temperature needs to be reduced by 5 ℃ / 1000m