Plastic Case Din Rail MDR-60W power supply

Peculiarity:

· International universal voltage input range: 85-264VAC/120-370VDC

· Protection type: short circuit/over power

· Natural air cooling

· Up to 90% work efficiency

· DC OK relay detection function

· Standby power consumption as low as 0.3W

· 100% full load burn-in test

· 2-year warranty

Categories: ,
MDR-60   60W rail type switching power supply
Project Tehnical index
Output DC voltage 5V 12V 24V 48V
Rated current 10A 5A 2.5A 1.25A
Rated power 50W 60W 60W 60W
Ripple and noise ① <80mV <120mV <150mV <200mV
Voltage accuracy ±2% ±1% ±1% ±1%
Output voltage
regulation range
 ±10%
Load adjustment rate ±1.5% ±1% ±1% ±1%
Linear adjustment rate ±1%
Input Voltage range 85-264VAC 47Hz~63Hz (120VDC~370VDC)
Efficiency(typical) ② >78% >86% >88% >87%
Working current <1.8A 110VAC   <1A 220VAC
Impulse current 110VAC  35A,   220VAC  70A
Start,rise hold time 500ms、30ms、25ms :110VAC             500ms、30ms、120ms :220VAC
Protect Overload protection 105%-150%  type:protection mode:automatic recovery after
belching mode abnormal conditions are removed
Overload protection When the output voltage is more than 135%,close the abnormanl
output condition and restart it for recovery
Environ mental science Working current -20℃~+70℃;20%~90RH
Storage temperature and humidity -40℃~+85℃;10%~95RH
Safety regulations Withstand voltage Input output:3KVAC   input ground:1.5KVAC  outpu ground  :0.5KVAC for 1 minute
Isolation resistance Input output,input shell,output shell :500VDC/100MΩ
Sther Size 40*90*100mm
Net weight/gross weight 330/350g
Remark ①Ripple and noise measurement method: use a 12″ twisted pair cable, and the terminals should be connected in parallel with 0.1uF and 47uF capacitors, and measure at a bandwidth of 20MHz.
②The efficiency is at an input voltage of 230VAC, rated load, and an ambient temperature of 25°C Under test. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear adjustment rate test method: from low voltage to high voltage under rated load test load adjustment rate test method: from 0%-100% rated load. The start-up time is measured in the cold start state. Rapid and frequent switching of the machine may increase the start-up time. When the operating altitude is higher than 2000 meters, the operating environment temperature needs to be lowered by 5°C/1000 meters.