DR-75 75W Din Rail Power Supply | ||||
Project | Technical index | |||
Output | DC voltage | 12V | 24V | |
Rated current | 6.3A | 3.2A | ||
Rated power | 76W | 76.8W | ||
Ripple and noise ① | <120mV | <150mV | ||
Voltage accuracy | ±2% | ±1% | ||
Ripple and noise | ±10% | |||
Load adjustment rate | ±1% | |||
Linear adjustment rate | ±0.5% | |||
Input | Voltage range / frequency | 85-264VAC 47Hz~63Hz (120VDC~370VDC) | ||
Efficiency (typical) ② | >86% | >88% | ||
Working current | <1.2A 110VAC <0.8A 220VAC | |||
Impulse current | 110VAC 20A, 220VAC 40A | |||
Leakage current | 1800ms、60ms、12ms :110VAC/1000ms、60ms、60ms :220VAC | |||
Protect | overload protection | 105%-150% Type:production mode:burp modde automatic recovery after the abnormal condition is lifted | ||
Short circuit protection | VO The output abnormal condition will be restored automatically after it is removed after the power is restarted | |||
Environmental Science | Working temperature and humidity | -10℃~+50℃;20%~90RH | ||
Working temp.and humidity | -20℃~+85℃;10%~95RH | |||
Safety regulations | Withstand voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P:0.5KVAC | ||
Leakage current | <1mA/240VAC | |||
Isolation Resistance | I/P-O/P, O/P-Shell, O/P-Shell :500VDC/100MΩ | |||
Other | size | 55.5*125.2*100mm | ||
Net weight / gross weight | 600/650g |
All Products, Din Rail
Din Rail DR-75W power supply Plastic appearance
Features :
·Universal AC input Full range
·Protections: Short circuit / Overload / Over voltage”Cooling by free air convection
·Can be installed on DlN rail TS-35/7.5 or 15lsolation classll
·LED indicator for power on
·No load power consumption<0.5W
·100% full load burn-in test
·3 years warranty