S-350 350W switching power supply | |||||||
project | Technical index | ||||||
output | DC voltage | 5V | 12V | 18V | 24V | 36V | 48V |
Rated current | 50A | 29A | 19.4A | 14.5A | 9.7A | 7.3A | |
Rated power | 250W | 350W | 350W | 350W | 350W | 350.4W | |
Ripple and noise ① | <150mV | <150mV | <150mV | <150mV | <240mV | <240mV | |
Voltage accuracy | ±2% | ±1% | |||||
Output voltage regulation range | ±10% | ||||||
Load adjustment rate | <±1.5% | <±1.2% | <±1.2% | <±1% | <±0.5% | <±0.5% | |
Linear adjustment rate | <±1% | ||||||
input | Voltage range | 90-132VAC/180-264VAC 47Hz~63Hz;254VDC~370VDC | |||||
Efficiency (typical) ② | >74% | >82% | >82% | >84% | >86% | >86% | |
Working current | <5.2 A 115VAC <2.8A 230VAC | ||||||
Impulse current | 110VAC 25A, 220VAC: 50A | ||||||
Start, rise, hold time | 200ms、50ms、20ms :230VAC | ||||||
protect | overload protection | 105% – 135% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | |||||
Overvoltage protection | Close output when ≥ 115% – 145% | ||||||
Undervoltage protection | Close output when ≤ 10% – 45% | ||||||
Short circuit protection | Close output | ||||||
Over temperature protection | Rth3: ≥ 65 ℃ fan start, ≥ 55 ℃ fan close, ≥ 80 ℃ close output (5v-15v) rth3: ≥ 70 ℃ fan start, ≥ 60 ℃ fan close, ≥ 85 ℃ close output (18v-48v) | ||||||
Environmental Science | Working temperature and humidity | -10℃~+50℃;20%~90RH | |||||
Storage temperature and humidity | -20℃~+85℃;10%~95RH | ||||||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | |||||
Leakage current | Input output < 6mA at 1.5kVac | ||||||
Leakage current | < 1.5mA at input-output 220VAC | ||||||
Isolation resistance | Input output, input shell, output shell: 500VDC / 100M Ω | ||||||
Other | size | 215*114*50mm | |||||
Net weight / gross weight | 874.1/936.3g | ||||||
Remarks | ① Ripple and noise measurement method: use a 12 “twisted pair, and connect 0.1uF and 47uF capacitors in parallel at the terminal, and measure at 20MHz bandwidth. ② The efficiency is tested at an input voltage of 230VAC, rated load, and an ambient temperature of 25 ℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear regulation test method: under rated load from low voltage to high voltage test load regulation test method: from 0% – 100% rated load. The start-up time is measured under the cold start state. The quick and frequent switch on and off may increase the start-up time. When the operating altitude is higher than 2000m, the operating environment temperature needs to be reduced by 5 ℃ / 1000m |
All Products, Enclosed Type
S-350W ACDC switching power supply 14.5A-29A
Features:
· Universal voltage input range: 90-132VAC/180-264VAC
· Protection type: short circuit/overcurrent
· Natural air cooling
· Work efficiency up to 84%
· 100% full-load burn-in test
· 2-year warranty
Reviews